Domain 3Security Architecture & EngineeringCORE

Physical Security & Environmental Controls

Physical security defense-in-depth, Crime Prevention Through Environmental Design (CPTED), HVAC, fire suppression classes (A, B, C, D, K), and perimeter controls.

Domain: Domain 3: Security Architecture and Engineering•Updated: 2026-08-26
#Physical Security#CPTED#Perimeter Security#HVAC#Fire Suppression#Mantraps#Power & UPS

CISSP Domain 3: Physical Security & Environmental Controls — Mindmap Review Study Guide

═══════════════════════════════════

PART 1: MERMAID MINDMAP

═══════════════════════════════════

mindmap
  root((Physical Security))
    Core Principles
      CIA triad achievement
      Touch the box
      Bypass controls
      Safety of people
    Control Categories
      Deterrent controls
      Delay controls
      Detective controls
      Assess controls
      Respond controls
    Layered Defense
      Defense in depth
      Preventive detective corrective
      Deterrent detective assess respond
    Facility Perimeter
      Fences and walls
      Minimize entrances exits
      Landscaping foliage
      Grading slope
    Surveillance and Sensors
      CCTV cameras
      Passive infrared devices
      Lighting
      Shock sensors
      Glass break sensors
      Timing attacks
    Access Control
      Card readers
      Contact systems
      Contactless RFID
      Badges
      Doors and mantraps
      Tailgating piggybacking
      Turnstiles
      Locks delay
      Mechanical locks
      Digital electronic locks
      Windows weak link
      Skimming
    Infrastructure Services
      Network connection
      Clean power
      UPS batteries
      Generators diesel
      Power outages degradation
      Blackouts and faults
      Brownouts sags dips
      Power surges
    HVAC Systems
      Temperature cooling
      Humidity static condensation
      ASHRAE ideal ranges
      Air quality filtering
      Positive pressurization
    Fire Detection
      Limit combustibles
      Flame infrared detectors
      Smoke detectors
      Ionization detectors
      Photo-electric optical detectors
      Dual detectors
      Heat thermal detectors
    Fire Suppression
      Water-based systems
      Wet-pipe systems
      Dry-pipe systems
      Pre-action deluge systems
      Gas-based systems
      INERGEN Argonite FM-200 Aero-k
      Halon banned
      Fire extinguisher classes
      Class C extinguishers
      CO2 suppression

═══════════════════════════════════

PART 2: TECHNICAL DEFINITIONS & CONCEPTS

═══════════════════════════════════

Core Principles

Physical Security — Critical for achieving confidentiality, integrity, and availability (CIA) through controls like UPS, generators, HVAC, and fire suppression.

“If you can touch the box, you own the box” — Expression meaning if an attacker gains physical access to a device (like a firewall or server), they can easily gain control of it.

Bypass Controls — Built-in hardware features like factory reset buttons that allow an attacker with physical access to bypass security and take control.

Safety of People — The primary, overarching goal of physical security; people are the most valuable asset and their safety must be prioritized above all else. ⚠️ EXAM TIP: Safety of people is the absolute primary goal of physical security, prioritized above protecting equipment or data.

Control Categories

Categories of Controls — The five categories of physical security controls, which must be implemented in this exact order:

  1. Deter
  2. Delay
  3. Detect
  4. Assess
  5. Respond

Deterrent Controls — Discourage trespassing, property damage, theft, and intrusion through signage and the environmental design of a building and surrounding land.

Delay Controls — Delay a risk from occurring, such as locks delaying an attacker from gaining unauthorized access.

Detective Controls — Detect if a risk has occurred, with CCTV cameras being a perfect example.

Assess Controls — Used to determine the method of attack and the target after an incident.

Respond Controls — Take appropriate actions to remediate the risk after it has been detected and assessed.

Layered Defense

Layered Defense / Defense in Depth — Implementing multiple layers of controls rather than a single control in isolation, ensuring that if one control fails, others remain.

  • Each layer should have a combination of preventive, detective, and corrective controls (or in physical security terms: deterrent, detective, and assess & respond controls).

Facility Perimeter

Perimeter — The first layer of defense protecting a facility, often an outside perimeter like a fence, followed by the exterior walls of the building.

Minimizing Entrances and Exits — The best way to secure the perimeter is to minimize the number of entrances, exits, and doors.

Landscaping — Refers to the foliage (trees and plants) around a building; must be maintained to provide clear sight lines for cameras and prevent attackers from climbing into the building.

Grading — Refers to how the land is sloped around a building; the ground should slope down and away from the building to keep it dry in the event of a flood.

Walls — Exterior and interior walls are critical to physical security to enclose and secure the building.

Surveillance and Sensors

CCTV (Closed Circuit Television) — Camera systems used as a deterrent and detective control, primarily detective, and can also be used for monitoring and auditing.

Passive Infrared Devices — Motion sensors that act as low-resolution cameras detecting infrared light (heat) emitted by objects; if a homeothermic mammal walks in, infrared light increases and movement is detected.

  • Must automatically recalibrate themselves if the ambient air temperature changes.

Lighting — An important physical security control; a well-lit building helps deter crime and is important for the safety of people.

Shock Sensors — Attached directly to a pane of glass to detect the small shockwave generated when a window breaks.

Glass Break Sensors — Sensors used to detect if the glass in a window has been broken.

Timing Attacks — Attacks that measure how long certain operations take (mentioned in the context of glass break/security sensors).

Access Control

Card Readers — Electronic systems used to control who is authorized to pass through a door into a building or specific rooms.

Type Mechanism
Contact Older magnetic readers; employee must swipe card through the reader.
Contactless Newer systems; employee only needs to hold card near the RFID reader.

Badges — Cards displaying an employee’s name and photo.

Doors — The primary way to control who can gain access to a building and specific parts of it.

Tailgating / Piggybacking — A social engineering attack where an intruder follows an authorized person through a door after they have unlocked it.

Mantraps — Specialized doors consisting of two doors, one after another; you unlock the first, enter a small space, close it, and only then unlock the second door to prevent tailgating/piggybacking.

Turnstiles — Specialized physical barriers used to prevent tailgating or piggybacking.

Locks — A perfect example of a DELAY control; it is just a matter of time before an attacker picks, forces, or breaks a lock, so they should never be implemented in isolation.

Category Examples
Mechanical Keyed locks, mechanical combination locks, magnetic locks.
Digital/Electronic Proximity/RFID locks, electronic combination locks, biometric locks.
  • Combination Locks: The complexity of the combination is one of the most important factors determining their security.

Windows — Often the weak link in the perimeter of a building; while there are various types of glass (plate, tempered, laminated, wired, polycarbonate), you do not need to memorize the glass types.

Skimming — Using an electronic device to steal card information from a valid transaction, such as installing a device on a bank machine/Point of Sale (POS) machine to record debit/credit details, or standing near a secure door to wirelessly record RFID communications from an employee card.

Infrastructure Services

Infrastructure — The three major infrastructure services critical to facility operation: Network, Power, and HVAC.

Network — A reliable connection to the internet (the largest distributed network) and/or to other locations of the organization.

Power — Providing a consistent supply of clean power, as most equipment requires electricity and businesses cannot function without electronic systems.

Clean Power — Alternating Current (AC) power that oscillates at a perfect 60 Hz with no noise or distortion in the line (a perfect sine wave), not referring to renewable sources.

UPS (Uninterruptible Power Supplies) — Basically giant batteries that provide instantaneous but short-term power until a generator can start up.

Generators — Typically large diesel engines connected to an alternator that provide long-term backup power for hours or days depending on fuel onsite.

Power Outages and Degradation

Type Definition
Blackout No power for a long period of time.
Faults A momentary loss of power.
Brownouts An intentional reduction of voltage by the utility company.
Sags & Dips A short period of low voltage.
Surges A momentary spike of too much voltage (e.g., lightning strike).

HVAC Systems

HVAC (Heating Ventilation and Air Conditioning) — Systems that provide air to a building at the correct temperature and humidity, and filter the air.

Temperature — The primary reason for bringing cool air into a data center is to cool the equipment and ensure it operates within a desired temperature range.

Humidity

  • Too dry: Results in static electricity.
  • Too humid: Results in condensation.

ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) — Defines the ideal temperature and humidity ranges for office buildings and data centers.

  • Ideal Temperature: 18 to 27 degrees Celsius (exam questions will list both Celsius and “Freedomheight”/Fahrenheit equivalents).
  • Ideal Relative Humidity: 40 to 60 percent.

Air Quality — The final major function of HVAC is to filter air to remove dust and contaminants; contaminants could clog equipment, causing shorts, overheating, and failure.

Positive Pressurization — Blowing nice, clean, filtered air into the datacenter at slightly above ambient pressure; if there are cracks or a door opens, clean air is forced out, preventing dirty air and contaminants from infiltrating.

Fire Detection

Fire Prevention — The best way to prevent a fire is to limit or eliminate any combustible materials.

Flame (Infrared) Detectors — Detect the Infrared and Ultraviolet light created by flames; essentially video cameras pointed at areas of concern.

Smoke Detectors — Detect smoke, which is always present before a fire, allowing for early detection.

Type Best Used For
Ionization Responds more quickly to flaming or fast fires.
Photo-electric (Optical) Responds more quickly to smoldering fires.
Dual Combines ionization and photo-electric into one device.

Heat (Thermal) Detectors — Also referred to as rate of rise detectors; essentially temperature sensors monitoring for a rapid rise in temperature.

⚠️ EXAM TIP: To detect a fire as early as possible, remember there is always smoke before a fire, and we are most concerned with flaming/fast fires, so pick ionization detectors.

Fire Suppression

Fire Suppression — Correcting a fire as quickly as possible after detection, using water-based or gas-based systems.

Fire Suppression Systems Comparison

Feature Water-based Systems Gas-based Systems
Cost Cheaper Cost justified in datacenters
Environment Office buildings, hotels Datacenters (water destroys equipment)
Mechanism Cools the fire Displaces oxygen or interrupts chemical exothermic process

Water-based Systems Details

  • Wet-pipe Systems: Always have pressurized water in the pipes waiting to be released; cheapest, but cannot be used where pipes might freeze and inevitably leak.
  • Dry-pipe Systems: Pipes are dry and filled with pressurized gas; water only floods into the pipes when needed.
  • Pre-action and Deluge Systems: Also use water to put out a fire.

Gas-based Systems — Use gas to put out fires by either displacing oxygen (no oxygen = no fire) or interrupting the chemical exothermic process of fire.

  • Safety Systems: Critical to allow people to exit before gas is released, as no oxygen also equals no human life.
  • Major Gas Agents: INERGEN, Argonite, FM-200, and Aero-k.

Halon — A gas traditionally used in datacenters but banned globally because it destroys the ozone layer. ⚠️ EXAM TIP: Do not pick Halon on the exam; it is bad for the environment and banned.

Fire Extinguishers — There are five different classes of fire extinguishers: A, B, C, D, and K, each meant for a different type of fire and using different agents.

Class C Extinguishers — Designed to put out electrical fires (like in a datacenter); often use CO2 as the suppression agent.

CO2 (Carbon Dioxide) — An excellent fire suppression agent for datacenters because it is non-corrosive (won’t damage equipment), leaves no residue, doesn’t conduct electricity, and is safe for humans provided you don’t use too much.